SKYLINE PROXIMITY READER V
AUTONOMOUS Technical Features:
Does not require physical reader-card contact. Reading distance at 5 cm (card) or 1.5 cm (keychain).
Acoustic and visual information of actions.
Manual or PC programming (card registration/deletion) is very simple.
Door sensor control and exit button
Relay output.
Door release activation by relay with programmable time. Programmable 1 to 99 sec.
Signaling LEDs (help with programming and status).
Autonomous Programming - It can be done in 3 ways:
By Master Card.
Private programming keyboard.
PC software.
MDS-AC Plus CENTRALIZED Technical Characteristics: -
It does not require physical reader-card contact. Reading distance at 5 cm (card) or 1.5 cm (keychain). - Acoustic and visual information of actions.
Door opener button input, door sensor input and door opener relay (C, NO, NC, potential free).
Reader Wiring – Central Unit: 2 wires (power supply) + shielded twisted pair (data). In an installation with several readers they can be connected in cascade.
It has a dipswitch (SW1) to configure: • Door Number (switches 1..5): the access/door number (0..31).
Switch 6: No function.
Door release opening (switches 7..8): depending on the installation:
Door release opening time (sec.) in MDS.
In AC Plus software configuration (switches without function).
Connector CN3: Keyboard connector.
The door openers can be connected directly to the reader and for maximum security installations use the relay decoder.
Centralized Programming Programming is carried out from the PC software corresponding to the installed central unit (ref. 2405 or ref. 4410).
CENTRALIZED Technical Characteristics with Wiegand 26 or Data/Clock protocol:
It does not require physical reader-card contact. Reading distance at 5 cm (card) or 1.5 cm (keychain).
Acoustic and visual information of actions.
Wiegand (WG) or Data/Clock readers allow the installation to be provided with greater anti-sabotage security by not connecting the door opening mechanism or the exit button connection to the reader. All devices are connected to the door controller and are therefore out of reach of manipulation. The door controller will be installed inside (safe zone) and the reader outside.
The reader can be used with other door controllers that use the Wiegand 26 (WG) or Data/Clock protocols.
Wiring: 7 wires to the door controller.
For more information, see Technical Characteristics of the door controller.
Centralized Programming Programming is carried out from the PC software corresponding to the installed central unit (ref. 2405 or ref. 4410).
Specifications Dimensions V (HxV mm): 105.2 x 47.5 Environmental protection (IP): 52 Shock protection (IK): 07 Power supply (V): Autonomous: 12V (ac/dc). Centralized: 12Vdc Consumption (mA) without lock release: 90 Operating temperature: -15 to 55ºC
Technology: GENERICA
Measures of the product: 105 x 48 mm
Weight: 0.24 kg
Measures of the packed product: 13,5x10x6 cm